HW 40152S(17Ah) cell

Name: HW 40152S(17Ah) cellModel:

Applicable scope:

Product details
Cell bar code and appearances:

40152S(17Ah)-.jpg  

Cell dimensions:     

  

40152S(17Ah)-2.jpg

Definition:

1.Rated capacity: 

Rated capacity =17Ah, the capacity obtained when a cell is discharged at 2-hour rate to voltage 2.5 V at 25±2.5 

2. Standard charge method:

At 25±2.5, charged to 3.65V at a constant current of 0.5C, and then, charged with constant voltage of 3.65V until the charged current drops below 0.01C. 

3.Standard discharge method:

At 25±2.5 , discharged to 2.5 V at a constant current of 1C.

Cell specification (fresh cell tested at 25±2.5, using standard charge and discharge unless otherwise specified)

ITEM

SPECIFICATION

Nominal capacity

17Ah @ 0.5C

Minimum capacity

16.5Ah @ 0.5C

Nominal voltage

3.2V

Max Charging voltage

3.65 ±0.05 V

Discharge ending voltage

2.5 ±0.05 V

Charge current

Standard charge: 0.5C
 Max charge: 2C when T≥10
Max charge: 1C when 10≥T≥0
Max charge: 0.1C when 0≥T≥-10

Discharge current

Standard discharge: 3C
Max discharge: 7C
Max instant discharge: 15C

Recommended charge & discharg cell surface temperature

Charge: 0~45    Discharge: -2060

Maximum allowable charge and temperature. Charging and discharging at these conditions will shorten cell cycle life.

Charge: 60
Discharge: 75

Humidity range

090%RH (none condensing)

Storage performance

25,100%SOC,28d capacity retention

6.0Ah

25,100%SOC,28d capacity recovery

6.3Ah

Storage requirements

Less than 1 year: -20~25

Less than 3 months: -20~45

30%~60%SOC, no water condensation

Internal resistance

2.5mOhm (AC Impedance, 1000HZ)

Cell dimension

Height: 165 mm Max 
Diameter: 41.0mm Max

Weight

~460 g


Electronic performance (fresh cell tested at 25±2.5, standard charge and discharge unless otherwise specified)

NO.

ITEM

CRITERION

5.1.1

Discharge rate capability

discharge capacity at 3C

16.3Ah

discharge capacity at 5C

15.8Ah

discharge capacity at 10C

15.3Ah

5.1.2

Cycle life

discharge capacity of 2000th cycle @ 100% DOD

13.6Ah

discharge capacity of 3000th cycle @ 100% DOD

11.9Ah

5.1.3

High-Low temperature discharge performance (0.5C discharge)

discharge capacity at -10 

10.2Ah

discharge capacity at 0 

12.7Ah

discharge capacity at 60 

16.5Ah

residual capacity after 3months storage

15.7Ah

recover capacity after 3months storage

16Ah


40152S(17Ah)-3.jpg


C-Rate

Medium voltage/V

Peak temperature/

Temperature rise/℃ Room temperature is 26

1C

3.17

30.1

4.1

3C

3.06

38.3

12.3

5C

2.98

44.3

18.3

7C

2.9

50

24

10C

2.75

56.1

30.1


40152S(17Ah)-4.jpg

Environmental and safety characteristics:

ITEM

TEST METHOD

CRITERION

Over discharge

Under the battery discharge to the cut-off voltage, then discharge with 0.1C,until the voltage of battery is zero.

No explosion, no fire, no leakage

Over charge

After the battery fully charge, overcharge with 0.5C for one hour.

No explosion, no fire, no leakage

reverse charge

After the battery fully charge, with 1/6C reverse current constant current charging for 8h.

No explosion, no fire, no leakage

130 high temperature

After the battery is fully charged, the battery is placed in the oven for 3 ~ 7 / min heating rate, the temperature rose to 130  after the start time, and (130 ± 2)  temperature range of security within 1h.

No explosion, no fire, no leakage

High and low temperature  impact

When the battery is fully charged, shelved at -40 for 1h, then shelved 1h at 85, do such cycle for 32 times, then remove under room temperature for 6h.

No explosion, no fire, no leakage

Vibration

When the battery is fully chargedput the battery on the vibration table of amplitude 2mm, frequency 10Hz-30Hz for one hour.

No explosion, no fire, no leakage, no deformation.

Free fall drop

After the battery fully charge, let the battery fall from a height of 1.0m to the hard wood with thickness of 20mm, each surface for once.

No explosion, no fire, no leakage

Soaking

After the battery fully charged, the battery was sink at room temperature, depth will be subject to immersion cell surface within 24 h, then take out under room temperature for 6 h.

No explosion, no fire, no leakage

Extrusion

After the battery is fully charged, the battery surface with special equipment was squeezed until the batteries dimensions changed to 1 ~ 3mm.

No explosion, no fire

Short circuit

When the battery is fully charged, with the internal resistance of not more than 50mΩ wires connecting to the battery positive and negative extremes for 1h.

No explosion, no fire, no leakage

Constant temperature / humidity / heat

After the battery fully charged the in the relative humidity of 90% ~ 95% of the constant temperature and humidity box, duration of 48 h, then take out under room temperature for 6 h.

No explosion, no fire, no leakage

Nail

A nail (diameter : 2.5~5mm) is penetrated vertically through the center of the fully charged cells.

No explosion, no fire, no leakage

Warning in handling the lithium-ion cell:

Don’t immerse the cell in water;

Don’t use and leave the cell near a heat source such as fire or heater;

When charging, use a cell charger specifically for that purpose;

Don’t reverse the positive and negative terminals;

Don’t discard the cell in fire or heater;

Don’t connect the cell to an electrical outlet directly;

Don’t discard the cell in fire or heater;

Don’t connect the positive and negative terminal directly with metal objects;

Don’t transport and store the cell together with metal objects such as necklaces, hairpins;

Don’t directly solder the cell;

Don’t pierce the cell with a nail or other sharp object.

Don’t leave the cell with low SOC for long time, it should keep the cell with around 50% for long term storage (less than 6 months). Should charge the cell to 50% SOC after each 6 months.

Shipping and storage:

1.Shipping

The outer packaging should be firm enough, waterproof, and have a certain heat insulation effect; The interior should be filled with buffer materials, so as to avoid safety accidents caused by collisions during transportation of the battery. Cells should be kept SOC around 30-70%SOC during the time.

2.Long time storage

1) Storage conditions: keep the place clean and dry; Keep the cell terminals clean and free of dirt; Do not place heavy debris and liquid containers on the cell; The storage place should be free from inflammable, explosive, toxic and other chemicals and other corrosive gases, free from strong mechanical vibration and impact, and avoid strong electromagnetic field and sunlight. Recommended storage conditions are as follows:

2) If the cell is stored for long time, it should be carried out under the conditions specified in “4.Cell specification-storage requirements”, and the cell should be charged and discharged every 3 months.

Warranty:

1)The cells have 1 year quality assurance since the departure of the factory (otherwise stipulated in the contract shall prevail).

2)The company is not responsible for any problems caused by the combination of the circuit, battery pack and charger.

3)The company does not guarantee the quality of defective cells produced by customers during the battery assembly process after shipment.

4)The company does not assume any responsibility for any problems arising out of operation in violation of safety rules.